It appears you have not yet registered with our community. To register please click here...

Machine Underground -Tractor & Commercial Equipment Discussion Forum
 

Better Outdoor Products

The Quick™ was designed from the start to be the best deal going in a wide cut commercial walk behind mower.

Emerich Sales & Service Inc.

Emerich Sales & Service Inc. has been in business since 1968. We carry Kubota, Cub Cadet, Toro, Echo, Exmark, WheelHorse, and much more!

Van's Implement

For parts, sales, or service we have what you need. Major brands including Dixon, Woods, Encore, Zipper, Simplicity, and Massey Ferguson!

Eureka Fluid Film

Fluid Film® is a lanolin based rust/corrosion preventive and lubricant that provides long term protection and lubrication for all metal surfaces.

Markham Welding

Markham Welding designs and manufactures high quality skid steer attachments for any universal style skid loader or compact tractor.

Register Now!


Register FAQ Members List Calendar Active Topics Mark Forums Read

Reply
 
LinkBack Thread Tools Display Modes
Old 01-29-2008, 08:14 PM   #1 (permalink)
Rara Avis
PaulChristenson's Avatar
 
Status: PaulChristenson is offline
Join Date: Nov 2007
Location: Vermont
Posts: 1,899



Default Myth #1. Hydraulic pump inlet lines must have a strainer.

Myth #1. Hydraulic pump inlet lines must have a strainer.

A pump inlet or suction strainer is a 140 micron, mesh screen
which is screwed onto the pump intake penetration inside the
hydraulic reservoir.

These stainers increase the chances of cavitation occurring
in the intake line and subsequent damage to, and failure of
the hydraulic pump. Piston-type pumps are particularly vulnerable.

If the reservoir starts out clean and all fluid returning
to the reservoir is filtered, inlet strainers are not required
since the hydraulic fluid will not contain particles large enough
to be captured by a coarse mesh screen.


The main argument for installing suction strainers is to protect
the pump from debris that enter the reservoir as a result of
careless maintenance practices.

Fact is, nuts, bolts, tools and similar debris pose minimal threat
to the pump in a properly designed reservoir, where the pump intake
is located a minimum of four inches off the bottom.

When you consider the damage that vacuum-induced cavitation can
cause to a hydraulic pump, NOT installing a suction strainer is
definitely the lesser of two evils.

I generally recommend removing and discarding all filters fitted
to pump intake lines. The one possible exception to this rule
is charge pump intakes on hydrostatic transmissions.

If in doubt, consult the hydraulic pump manufacturer.

On the last paragraph...YMMV...

Paul in VT

I used to own an ant farm but had to give it up. I couldn't find tractors small enough to fit it.
-- Steven Wright
 
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Sponsored Links
Old 01-30-2008, 10:32 AM   #2 (permalink)
Member
 
Status: lincolnvt is offline
Join Date: Oct 2007
Posts: 62



Default

Thanks Paul - very useful info and fun to read. Appreciate your time with this.

Cheers,
Brad
 
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old 01-30-2008, 02:29 PM   #3 (permalink)
Senior Member
Mickey's Avatar
 
Status: Mickey is offline
Join Date: Nov 2007
Location: Oregon
Posts: 1,065



Default

Paul, you comments remind me of a few yrs back when I replaced the trans filter on the motorhome. Had to drop the pan and what do I see, a metal housing with window screen sized mesh for the filter. Like that was going to really help!

1970 Bolens 1257 w/tiller
2005 Cub 3204 48" deck
Yanmar Fx24D
5' Howse rotary mower
RSB 1300 Yanmar tiller
 
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old 09-10-2008, 06:34 PM   #4 (permalink)
Member
 
Status: mighty mouse is offline
Join Date: Aug 2008
Location: Wayne County Pa
Posts: 60



Default

Wow, I was absolutely crucified on another site for suggesting this. I was told by an engineer at the factory of a major equipment manufacturer that the only reason they install suction strainers is to cut down on warranty claims from stuff left in the hyd tank by the asemblers. I have also seen the window screen type get sucked shut when the pump ran. Turn the engine off, remove the strainer, it looks fine, run the pump, the strainer collapses. I have always removed these from my equipment on the first service and have never had a breakdown that a suction strainer would have prevented.
 
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old 09-11-2008, 01:14 PM   #5 (permalink)
Senior Member
Dougster's Avatar
 
Status: Dougster is offline
Join Date: Mar 2008
Location: Eastern MA
Posts: 2,063



Default

Quote:
Originally Posted by PaulChristenson View Post
Myth #1. Hydraulic pump inlet lines must have a strainer.

A pump inlet or suction strainer is a 140 micron, mesh screen
which is screwed onto the pump intake penetration inside the
hydraulic reservoir.

These stainers increase the chances of cavitation occurring
in the intake line and subsequent damage to, and failure of
the hydraulic pump. Piston-type pumps are particularly vulnerable.

If the reservoir starts out clean and all fluid returning
to the reservoir is filtered, inlet strainers are not required
since the hydraulic fluid will not contain particles large enough
to be captured by a coarse mesh screen.

The main argument for installing suction strainers is to protect
the pump from debris that enter the reservoir as a result of
careless maintenance practices.

Fact is, nuts, bolts, tools and similar debris pose minimal threat
to the pump in a properly designed reservoir, where the pump intake
is located a minimum of four inches off the bottom.

When you consider the damage that vacuum-induced cavitation can
cause to a hydraulic pump, NOT installing a suction strainer is
definitely the lesser of two evils.

I generally recommend removing and discarding all filters fitted
to pump intake lines. The one possible exception to this rule
is charge pump intakes on hydrostatic transmissions.
If in doubt, consult the hydraulic pump manufacturer.

On the last paragraph...YMMV...
The old Dougster™ is a little confused. What specifically are you folks saying or recommending as it relates to our equipment? That we should remove the hydraulic system suction filters and/or strainers on our tractors and other mobile equipment?

Not trying to start a debate or technical argument. To the contrary, I promise to be quiet for once and listen and not post again in this thread. Just trying to figure out specifically what you guys are recommending to us here.

Dougster™
 
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old 09-11-2008, 01:25 PM   #6 (permalink)
Member
 
Status: mighty mouse is offline
Join Date: Aug 2008
Location: Wayne County Pa
Posts: 60



Default

Doug,

Just saying that in a properly designed hydraulic system, the strainer poses more problems than it solves. When strainers get clogged, it is with gooey oil residue, not with nuts, bolts, and pieces of metal. All that stuff would go right thru the pump and components without causing any damage. The outlet from the tank to the pump should be up off the bottom anyway, so no steel should ever be picked up. When changing the hydraulic oil, the tank should be cleaned also, so anything in the bottom of the tank will be cleaned out anyway. Hope this clears it up for you.
Andy
 
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules Sponsor
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT -4. The time now is 02:14 AM.
Powered by vBulletin®, Copyright ©2005 - 2008, MachineUnderground.com
vBCredits v1.4 Copyright ©2007 - 2008, PixelFX Studios



Content Relevant URLs by vBSEO 3.1.0